Textolite in Moisture, Oil and Elevated Temperatures

Using Textolite in moisture, oil and elevated temperatures requires selection of a specific grade and assessment of the complete operating system. Standard TCF cotton phenolic sheets are described as materials for operation in oil and in air at normal humidity. This does not mean, however, that every Textolite component is suitable for continuous immersion, any lubricant or operation at a limiting temperature.

Textolite sheet and sleeve assessed for exposure to water oil and temperature
Operating conditions affect the selection of Textolite for an application.

When ordering a sleeve, guide or insulating spacer, provide the operating conditions as well as the dimensions. This makes it possible to check whether the requirements are consistent with the material documentation and component design.

Why does the Textolite grade matter?

Textolite consists of cotton fabric and cured phenolic resin. Grades differ, among other things, in fabric structure and intended use. For example, PFCC202, also encountered as TCF-1, is described as a grade for electrical applications with reduced water absorption. This does not mean zero absorption or suitability for every damp installation.

Before selecting a material, consult the planned guide to TCF and PFCC Textolite grades. For rods, tubes and sleeves, use documentation for the relevant stock form instead of automatically applying sheet data.

Textolite and moisture — what must be checked?

Normal atmospheric humidity, occasional splashing and continuous immersion are different operating conditions. Suitability assessment must consider water absorption and the required properties after conditioning. For an insulating component, electrical data corresponding to the expected moisture exposure are important.

For a fitted component, it is also necessary to assess whether humidity could affect the required dimensions and clearances. This assessment should be based on data for the grade or on testing under conditions close to actual service.

For example, a bush in an enclosed, lubricated housing and a bush that is regularly washed with water require separate checks. State the cleaning frequency, liquid temperature, contact time and cleaning agents used. The phrase “moisture resistance” alone is too broad for material selection.

Can Textolite operate in oil?

Operation in oil is a common application for appropriately selected cotton phenolic laminates. For sliding components, however, the oil type, its temperature, the supply method and the load conditions must be defined. Suitability for oil does not confirm resistance to every formulation or to water-oil emulsions.

In your enquiry, state the lubricant’s trade name and attach its technical data sheet if available. Note the presence of water, process additives or contaminants. Do not equate the ability to operate in oil with maintenance-free bush operation.

Assembly selection is discussed more broadly in the planned guide Textolite for Bushes and Plain Bearings. Oil impregnation or thermal preparation of the material requires an agreed procedure for the specific grade and application.

What operating temperature is permissible?

120°C is often stated as a continuous operating temperature for standard TCF sheets. This catalogue information must be confirmed for the grade supplied. By itself, it is not a basis for assuming that every bush, guide or insulator will operate correctly at that temperature.

Distinguish ambient temperature, medium temperature and local component heating. Heat generated by friction must be considered in a sliding assembly. State the operating duration, heating and cooling cycles, and maximum temperature excursions.

A short-term exposure temperature is not the same as a continuous operating temperature. Textolite is a thermoset and does not melt like a thermoplastic, but overheating can cause degradation and brittleness. Retention of shape does not confirm retention of mechanical or electrical properties.

Operating conditions — what information should be prepared?

ConditionWhat should the enquiry include?What requires assessment?
Humid airHumidity range, temperature and possibility of condensationProperties after moisture exposure and dimensional requirements
Washing or splashingLiquid type, contact time and frequencyGrade suitability for repeated contact with the medium
Continuous immersionMedium composition, temperature and expected service durationDocumentation or testing under actual conditions
Operation in oilOil name, temperature, lubrication method and loadMaterial compatibility with the medium and assembly requirements
Elevated temperatureComponent temperature, operating time and thermal cyclesGrade and design parameters at the required temperature

Moisture, oil and temperature may occur together

Suitability for one condition does not determine performance when conditions are combined. For example, an oil-lubricated component may also be loaded, heated locally and washed periodically. Describe the full cycle, including start-up, steady-state operation, shutdown and cleaning.

If the requirements include low water absorption or a different thermal class, alternative laminates should be compared. The planned article Textolite or Glass Epoxy — Which Laminate Should You Choose? may help. A material change requires confirmation of every function of the component.

Frequently asked questions

Is Textolite waterproof?

The material name must not be treated as a guarantee of underwater service. The grade, contact time, temperature and component requirements must be consistent with the documentation or verified by testing.

Is every oil suitable for lubricating a Textolite bush?

This cannot be assumed without verification. Assessment requires information about the oil and about the assembly’s load, speed and temperature.

Does 120°C apply to every Textolite product?

No. This is a commonly stated value for standard TCF sheets. The grade, stock form, design and operating conditions require separate confirmation.

Do you need Textolite or a finished component made to size?

Send the drawing, dimensions, tolerances and quantity. Include the temperature, contact with water or oil, load and installation method. Ekonit sp. z o.o. will check stock availability and whether the component can be manufactured to the documentation.

For the information needed to order a cut blank, see the planned guide to Textolite Sheet Cut to Size — Ordering and Price.

Send a quotation request →

General requirements for industrial rigid laminated sheets for electrical purposes are also described in IEC 60893-1; material selection must nevertheless be based on the actual application conditions.